TYPE OF PERFORMANCE
TYPE OF PERFORMANCE
Impact resistance
With the right boards and systems in place, plasterboard can provide extremely tough partitions, ceilings and linings. With the right board choice, a severe duty performance can be provided from a single 12.5 mm layer partition, suitable for busy, high traffic areas like schools, hospitals, detention centres and shopping centres.
Our impact resistant products
Filters
S4915 profile - Ceiling clip system
Galvanized steel profile C 15/49/15, 6/10 mm thick, for suspended click ceilings by Guida Clip
PregyPlac Plus BA10
Standard plasterboard, 9,5 mm thick, with added glass fibers in the core for the realization of curved surfaces
28/28/28 U track
Galvanized steel track U 28/28/28 , 6/10 mm thick, for S 4927, S6027 and Omega 27 profile
Our impact resistant Partitions
Filters
Pregy SL310/2M100 - 4 PS BA15
Double frame high partition with double layer of PregyPlac BA15 boards on each side
Pregy SL350/2M100 - 4 PS BA13 - MW/80 + 80
Double frame high partition with double layer of PregyPlac BA13 boards on each side and mineral wool in the cavity
Pregy CSO 40/S4927 - 1 LaDura BA13
Single frame ceiling with single layer of LaDura Plus BA13 and optional mineral wool in the cavity
Pregy CW80/M50 - 2 PF BA15 - GW/45
EI 60 stand alone lining with double layer of PregyFlam BA15 fixed to C studs and glass wool in the cavity
Pregy SL360/2M100 - 4 PS BA15 - MW/80 + 80
Double frame high partition with double layer of PregyPlac BA15 boards on each side and mineral wool in the cavity
Pregy D160/M100 - 2 PS BA15 + 2 LaDura BA15
160 mm thick partition with 1 x PregyPlac BA15 + 1 x LaDura Plus BA15 boards on each side
Pregy D160/M100 - 4 PS BA15
160 mm thick partition with double layer of PregyPlac BA15 boards on each side
Pregy D125/M75 - 4 PF BA13 - GW/70
125 mm thick partition with double layer of PregyFlam BA13 boards on each side and glass wool in the cavity
Pregy D135/M75 - 2 PS BA15 + 2 LaDura BA15 - MW/60
135 mm thick partition with 1 x PregyPlac BA15 + 1 x LaDura Plus BA15 boards on each side and mineral wool in the cavity
Pregy CW88/M75 - 1 AQB BA13 - MW/60
Lining with single layer of PregyAquaBoard BA13 fixed to C studs and optional mineral wool in the cavity
Pregy D200/M150 - 4 PS BA13
200 mm thick partition with double layer of PregyPlac BA13 boards on each side
Pregy CDO 67/S4927 - 1 PH BA13
Double frame ceiling with single layer of Pregydro H2 BA13 and optional mineral wool in the cavity
Pregy D110/M50 - 2 PS BA15 + 2 LaDura BA15
110 mm thick partition with 1 x PregyPlac BA15 + 1 x LaDura Plus BA15 boards on each side
Pregy D125/M75 - 4 LaDura BA13 - MW/60
125 mm thick partition with double layer of LaDura Plus BA13 boards on each side and mineral wool in the cavity
Pregy D135/M75 - 4 PS BA15
135 mm thick partition with double layer of PregyPlac BA15 boards on each side
Pregy D136/M100 - 2 PS BA18 - MW/80
136 mm thick partition with single layer of PregyPlac BA18 boards on each side and mineral wool in the cavity
Pregy D150/M100 - 4 LaDura BA13
150 mm thick partition with double layer of LaDura Plus BA13 boards on each side
Our impact resistant Linings
Filters
Pregy SL310/2M100 - 4 PS BA15
Double frame high partition with double layer of PregyPlac BA15 boards on each side
Pregy SL350/2M100 - 4 PS BA13 - MW/80 + 80
Double frame high partition with double layer of PregyPlac BA13 boards on each side and mineral wool in the cavity
Pregy CSO 40/S4927 - 1 LaDura BA13
Single frame ceiling with single layer of LaDura Plus BA13 and optional mineral wool in the cavity
Pregy CW80/M50 - 2 PF BA15 - GW/45
EI 60 stand alone lining with double layer of PregyFlam BA15 fixed to C studs and glass wool in the cavity
Pregy SL360/2M100 - 4 PS BA15 - MW/80 + 80
Double frame high partition with double layer of PregyPlac BA15 boards on each side and mineral wool in the cavity
Pregy D160/M100 - 2 PS BA15 + 2 LaDura BA15
160 mm thick partition with 1 x PregyPlac BA15 + 1 x LaDura Plus BA15 boards on each side
Pregy D160/M100 - 4 PS BA15
160 mm thick partition with double layer of PregyPlac BA15 boards on each side
Pregy D125/M75 - 4 PF BA13 - GW/70
125 mm thick partition with double layer of PregyFlam BA13 boards on each side and glass wool in the cavity
Pregy D135/M75 - 2 PS BA15 + 2 LaDura BA15 - MW/60
135 mm thick partition with 1 x PregyPlac BA15 + 1 x LaDura Plus BA15 boards on each side and mineral wool in the cavity
Pregy CW88/M75 - 1 AQB BA13 - MW/60
Lining with single layer of PregyAquaBoard BA13 fixed to C studs and optional mineral wool in the cavity
Pregy D200/M150 - 4 PS BA13
200 mm thick partition with double layer of PregyPlac BA13 boards on each side
Pregy CDO 67/S4927 - 1 PH BA13
Double frame ceiling with single layer of Pregydro H2 BA13 and optional mineral wool in the cavity
Pregy D110/M50 - 2 PS BA15 + 2 LaDura BA15
110 mm thick partition with 1 x PregyPlac BA15 + 1 x LaDura Plus BA15 boards on each side
Pregy D125/M75 - 4 LaDura BA13 - MW/60
125 mm thick partition with double layer of LaDura Plus BA13 boards on each side and mineral wool in the cavity
Pregy D135/M75 - 4 PS BA15
135 mm thick partition with double layer of PregyPlac BA15 boards on each side
Pregy D136/M100 - 2 PS BA18 - MW/80
136 mm thick partition with single layer of PregyPlac BA18 boards on each side and mineral wool in the cavity
Pregy D150/M100 - 4 LaDura BA13
150 mm thick partition with double layer of LaDura Plus BA13 boards on each side
Follow #Siniat on social media: